PENG Qiyu, LIU Yulan, WANG Biao. Response analysis of nuclear power plant containment under earthquake and internal pressure[J]. Acta Scientiarum Naturalium Universitatis SunYatseni, 2019,58(6):73-80.
PENG Qiyu, LIU Yulan, WANG Biao. Response analysis of nuclear power plant containment under earthquake and internal pressure[J]. Acta Scientiarum Naturalium Universitatis SunYatseni, 2019,58(6):73-80. DOI: 10.13471/j.cnki.acta.snus.2019.06.009.
For the research on the safety limit of nuclear power plant containment under extreme conditions (i.e. being subjected to earthquake and internal pressure simultaneously)
a detailed three-dimensional finite element model for containment of CPR1000 was established. Considering the nonlinear properties of materials
the acceleration
displacement and strain responses of nuclear containment under seismic load
internal pressure and combination of them were simulated by ABAQUS software. As the result has shown: 1)When the concrete cracking area of the containment penetrates the inner and outer layers
the nuclear leaks may occur
which is regarded as the safety limit of the containment. So when the internal pressure is applied only
the anti-pressure safety limit of the containment is 120 kPa. 2)Comparing with the containment under the seismic load of 0.2 g simultaneously
the safety limit becomes 100 kPa
which decreases by 16.7%. 3)Likewise
the seismic safety limit of containment is 0.4 g when there is only seismic load. But when it is subjected to internal pressure of 50 kPa
limit downs to 0.3g
which is reduced by 25 %. 3)In addition
the acceleration and displacement responses of the containment have no much change under the simultaneous load of the internal pressure below 100 kPa and the earthquake below 0.4 g
comparing with applying them respectively.
关键词
核电站安全壳非线性地震响应内压
Keywords
nuclear power plantcontainment vesselnonlinearseismic responseinternal pressure